Ultimate
12/24 zone multifunctional alarm system with built in GSM communicator
|
The main characteristics of the device
- 12/24 zone multifunctional alarm system with built in GSM communicator
- handling two independent partitions that can also be armed/disarmed from an independent external device
- storing 576 events with date and time
- LCD keypad with transparent menu system, easy and quick to program
- Telephone calls with recordable voice messages (12 pieces of 5 second-long messages)
- Sending SMS messages with user and zone identification (e.g. OPENING THE SHOP: THOMAS )
- Signalling to monitoring station (CONTACT-ID)
- Differentiating 47 kinds of events
- 4 telephone numbers for the alarm calls and SMS
- 2 telephone numbers for Contact ID signals
- Handling 12 users (12 user codes with 4 – 6 digits)
- Arming/disarming by telephone, enquiry on state, relay control and voice recording
- Free Ultimate Remoter program for PC for the functions as follows
- Programming the module on serial port or by remote download
- Complete remote diagnostics, power supply, battery voltage, overcurrent monitoring, control of zones and outputs, inspection of event memory.
Technical information:
- Power supply: 16V-18V / 50Hz AC
- Average power consumption: 200mA
- Operational temperature: 0-60 °C
- Size: 202x124 mm
- Accessories:
- GSM antenna (900/1800 MHZ) + cable
- Plastic fixing mounts (4 pcs)
- Accumulator cable
- 1k Ohm resistor (40 pcs)
- Proposed external elements:
- Transformer: 16V / 40 VA
- Accumulator: 12V / 7Ah
- Keypad / programmer: SATEL CA 64 LCD (maximum 8 pcs)
- Inputs:
- 12 zones, maximum 24 sensors
- Installation methods (can be chosen by each zone)
- Short circuit activated
- Activated by circuit opening
- DEOL: closed by resistor (monitoring sabotage)
- 1 or 2 sensors / zone
- 2 inputs (A,B) for activation or deactivation with DEOL closure
- 1 analogue voltage input (reserved)
- Outputs:
- Keypad power supply (+KPD): 12V~0.5A DC
- Sensor power supply (+12 V): 12V~0.5A DC
- OUT1 (internal signalling device): 12V~1A DC
- OUT2 (external signalling device): 12V~1A DC
- RELAY1 (independent, NO/NC)
- RELAY2 (independent, NO/NC)
- RELAY3 (independent, NO/NC)
- Program connector RS–232 serial connector for PC programming
- Charging of accumulator Cyclical, voltage controlled charge, max. 800mA charging current